Item | Test method | Unit | Result |
Electrical resistance | SJ/T11236-2001 | ohm | 10^6-10^9Ω |
Wear resistance | EN 660-2:1999 | Group P | |
European classification | EN 649 | class | 34-43 |
Fire resistance | EN 13501-1:2007 | Bfl-S1 | |
Dimensional stability | ISO23999:2008 | % | ≤ 0.12 |
Slip resistance (oil-wet ramp test) | DIN 51130:2014-02 |
R9 | |
Residual indentation | ISO24343-1:2007 | mm | ≤ 0.05 |
Color Fastness To Light | ISO 105-B02:2014 | 8 | |
Effect of a castor chair | ISO 4918:2009 | No visible damage | |
Curling | ISO23999:2008 | mm | > -0.52 |
Resistance to staining | ISO26987:2008 | Index 0: Not affected | |
Content of Pentachlorophenol (PCP) | EN14041:2004 | ND | |
Formaldehyde emission | EN14041:2004 | ND Class E1 |
|
Water-tightness | EN14041:2004 | No sign of penetrating water.PASS | |
Thermal resistance | EN 14041 | (㎡·k)/w | 0.040 |
Thermal conductivity | EN 14041 | W/(m·K) | 0.057 |
SVHC | EN 14041:2004 | < 0.1% | |
Sound insulation of building elements | ISO 10140-1:2010 | dB | 6 |
Determination of flexibility | ISO24344:2008 | No cracking |